R Series

Category:

Product Description

brenner-r1_th

R Series

R1 Series

B u r n e r t y p e R1 ( - L ) R1- V ( - L )
Burner capacity 1.2 - 4.5 kg/h=14 - 53 kW 1.0 - 4.5 kg/h=12 - 53 kW
recommended boiler capacity 12.5 - 48 kW 11-41 Mcal/h 11 - 48 kW 9.5-41 Mcal/h
Voltage 230 V/ 50 Hz 230 V/ 50 Hz
max. current consumption 1.9 A 2.7 A
Motor 90 W 90 W
Oil pump(gear flow capacity) 54 l/h  54 l/h
Weight in kg 12 12
Noise emission in dB (A) 62 62
r1_output
r1_adjust
r1_dim
Mode Of Operation Burner Order no.
Single-stage R1 11-36-40103-02
Single-stage R1-V 11-36-40145-02
Single-stage R1-V-L 11-36-40231-02
Version for warm Air heater with controller DKW 972, Single stage R1-WLE 11-36-40241
Version for warm Air heater with controller DKW 972, Single stage R1-V-WLE 11-36-40158

R20-30

Technical data R20-(L) R20-V(-L) R20-(L)-AE R20-ZS-L R30-AE R30-Z-L
n. burner output in kW 36 36 36 95
Max. burner output in kW 166 77 166 273
Min. boiler output in kW 33 31 33 87
Max. boiler output in kW 153 71 153 251
Fuel oil Type EL, to DIN51603
Method of operation 1-stage 1-stage 1-stage with startup relief 2-stage 1-stage with startup relief 2-stage
Voltage 1 / N / PE ~50 Hz / 230 V
Current consumption Max. start / operation in A 2.3 / 1.1 3.2 / 2.0 2.3 / 1.1 2.8 / 1.6
Electric motor (2850rpm) in W 180 250
Oil pump in l/h 54 70
Photoelectric cell MZ 770S
Control box TF 830/832, DKW 972 (WLE)
Weight in kg 16.5 17.8 17.5 18.5 29
Noise emission in db(A) ≤ 73 ≤ 68 ≤ 73 ≤ 73 ≤ 75
rg20_output
rg20_adjust

R20-30 Dim

R20-30 Order no.

Mode Of Operation Burner Order no.
Single-stage R20 12-36-40175-02
Single-stage R20-AE 12-36-40182-02
Version for warm Air heater with controller DKW 972, Single stage R20-WLE 12-36-40183
Version for warm Air heater with controller DKW 972, Single stage R20-AE-WLE 12-36-40184
Oil control,fitted 47-30-21762
Mode Of Operation Burner Order no.
Single-stage R30-AE 13-36-40235
Two-stage R30-Z-L 13-36-40238
Version for warm Air heater with controller DKW 972 R30-AE-WLE 13-36-40261
Version for warm Air heater with controller DKW 972 R30-Z-L-WLE 13-36-40262
Oil control,fitted 47-30-21763

R1 Nox

R1-V-L-BI NOX R1-V-L-BI NOX R1.2-V-BI-NOX R1.2-V-L-BI NOX
Burner output in kW 16-33 16-33 28,4-50 28,4-50
oil flow rate  in kg/h 1,35-2,8 1,35-2,8 2,4-4,2 2,4-4,2
Burner output at nk=92%  kW 14,7-30 14,7-30 26,2-46,5 26,2-46,5
Motor W 90
Mode of operation single-stage
Voltage 1 / N /PE ~ 50 Hz / 240 V
oil pre heater W 30-110
Flame failure control unit MZ 770 IRD 1010
Control box TF 830.3
r1nox_output
r_dim
Mode Of Operation Burner Order no.
Single-stage R1-V-BI-NOX 11-36-41101
Single-stage R1-V-L-BI NOX 11-36-41100
Single-stage R1.2-V-BI-NOX 11-36-41264
Single-stage R1.2-V-L-BI NOX 11-36-41263
Oil control, fitted 47-30-21761
Recirculation attachment cpl. R1-V-(L)-BI-NOX 47-90-12655
R1.2-V-(L)-BI-NOX 47-90-24794

R20 Nox

R20-V-L-BI NOX R20-V-L-BI NOX
Burner output in kW 33-80 33-80
oil flow rate  in kg/h 2,8-6,7 2,8-6,7
Burner output at nk=92%  kW 30-73,6 30-73,6
Motor W 180
Mode of operation single-stage
Voltage 1 / N /PE ~ 50 Hz / 240 V
oil pre heater W 30-110
Flame failure control unit MZ 770
Control box TF 830.3
r20nox_output
r_dim
Mode Of Operation Burner Order no.
Single-stage R20-V-BI-NOX 11-36-41305
Single-stage R20-V-L-BI NOX 11-36-41306
Oil control, fitted 47-30-21762
Recirculation attachment cpl. R20-V-(L)-BI-NOX 47-90-24331